It seems like the easier hack would be to put a peltier heater/cooler under the thermostat then control that remotely to assume control over what temperature the thermostat sees.
The link to the exact model of thermostat isn't working, so I don't know how amenable its design is to this approach, but the thermostats I've used are generally wall-mounted and putting a heat/cool source under them wouldn't be too hard. You'd need to make sure that you didn't send both the heat and cool into the thermostat, but that's a simple positioning problem.
looofooo0 34 minutes ago [-]
Actually the best control system for such a boiler would be to control the heating curve where heating water temperature is fixed to the outside temperature. If you aim for the lowest water temperatures possible, then the system will become quite slow reacting. Then you only need to adjust the flow of water to the individual rooms to fix varying temperature issue. But this is long term manual optimization process which takes 1 to 2 years to perfect.
paulkrush 2 hours ago [-]
Cool idea! It's ironic that this is such an efficient use case for device that is so inefficient.
catsma21 1 hours ago [-]
yeah i put mine in the freezer
sokoloff 5 hours ago [-]
> I also have it so the heating turns off when I go into town and turns back on when I'm just a few train stops away so my place is nice and toasty for me getting home!
If your goal is saving energy/money, you don’t want a system capable of going from cool to toasty in 20 minutes.
Instead, you want a system that runs (much) lower water circulation temperatures (giving lower losses in the unconditioned spaces and more even room heating). That can be done to any condensing boiler by just turning down the flow target temperature.
A second layer of optimization on top of this is the addition of outdoor reset/weather compensation which will adjust that flow temperature based on the outside temperature, giving a flow temperature than can just barely restore the building to the desired setpoint temp.
With mine properly tuned, I was targeting having the thermostat act more like a high-limit and for it to call for heat between 22 and 24 hours per day while not overheating the house. That often meant flow temps in the 110°F (warm day) to 135°F (below freezing day) range. Compared to the prior winter (at a constant 160°F flow), the house used 8-15% less gas and was wildly more comfortable. (This setup does preclude using deep setback settings, which also can save money, because recovery times are necessarily long in such a scheme, unless you have an even smarter control system that can run perfectly tuned water most times but hotter water during recovery from setbacks.)
looofooo0 30 minutes ago [-]
Agree, switching on and off is the worst way of heating. If you look into ISO 7730, then a lot of comfort comes from no cold walls: https://de.wikipedia.org/wiki/ISO_7730
This means that in a reasonable insulated home, your best bet for comfort is to just keep the temperature constant and low like 20°C. This also allows you to lower your water temperatures which improves efficiency of your heat pump or boiler.
Retric 4 hours ago [-]
That’s an artifact of how heating is setup inside your home. Which is more efficient depends on where you’re dumping heat inside the home, levels of insulation, etc.
Energy moves from hot to cold linearly with temperature differences. Hypothetically, if the pipe was the same temperatures as the inside of your home all the heat transferred would be outside the envelope. The hotter the pipe the better this ratio becomes. This is true regardless of what percentage of the pipe is inside the envelope.
However, heating along the exterior of the home under windows and such then you’ll heat the exterior walls to higher temperatures than the interior thermostat thus losing more heat to the outside. Radiant heating on the other hand largely avoids this effect.
looofooo0 25 minutes ago [-]
Look at ISO 7730, a lot of comfort comes from non-cold walls and their radiant heat and small difference of wall temperatures to air temperatures. So having a thoroughly heated home allows you to lower you air temperature. Apart from that modern gas and even more heat pumps greatly gain efficiency by lowering flow water temperatures.
DamonHD 4 hours ago [-]
I moved all my radiators away from under windows (and upgraded the windows to triple glazing) to avoid maximising the temperature differential and energy loss through the wall under the windows, while eliminating the cool drafts that the under-window radiator placement was intended to counter.
Benanov 49 minutes ago [-]
Radiators were originally designed to heat more than needed, so you could open the windows.
Do you mean you moved them to another wall, or just increased the gap?
(not a native speaker here)
HPsquared 3 hours ago [-]
What do you do for ventilation?
31 minutes ago [-]
frereubu 5 hours ago [-]
I've read that it's always more efficient to turn heating off when you're not home and then turn it back on when you return. Is the reason for it being on 22-24 hours here that it takes a very long time to get back to the desired temperature, meaning you'd actually be cold for quite a while as it returned to the desired temperature?
leoedin 4 hours ago [-]
The hidden factor here is that condensing boilers and heat pumps have non-linear efficiency vs flow temperature curves. Heat pumps in particular show high increase in coefficient of performance (CoP) as flow temperature drops.
The other variable is how well controlled your heating is. A lower flow temperature means less overshoot of the target set point - and as losses scale linearly with temperature delta, that can mean higher energy losses (depending on the characteristics of the controller of course).
Whether or not you care about losses in unheated spaces depends on your system topology. Personally, all my heating pipes are within the thermal envelope of my house, so flow temperature has no bearing on those losses at all.
If you had a resistive electric boiler, flow temperature would have absolutely no effect on efficiency. You'd be completely right, that running heating only when you needed it would be more energy efficient.
looofooo0 12 minutes ago [-]
You missing ISO7730, it is a system for humans and not air temperature control. (tl;dr heating your home 24/7 allows you to lower air temperature for the same comfort. )
frereubu 2 hours ago [-]
Thanks for the explanation.
rsynnott 37 minutes ago [-]
> I've read that it's always more efficient to turn heating off when you're not home and then turn it back on when you return.
50 years ago this was _always_ the case, but condensing boilers and especially heat pumps muddy the waters a little. Condensing boilers can be close to 100% efficient (vs ~70-80% for ye olde gas boilers), but generally only at a fairly specific operating temperature, which may be lower than you'd need to get a rapid rise in temperature. Heatpumps are >100% efficient (that is for every joule of electricity you put in they move more than one joule), but are even more fussy about operating temperature.
The answer now is going to be a solid 'it depends', based on behaviour of the heating system, outside temp, desired inside temp, insulation...
looofooo0 22 minutes ago [-]
ISO 7730 to the help. Just keep low overall temperatures and heat 24/7 in a reasonably insulated home.
sokoloff 4 hours ago [-]
I work entirely remote so, other than travel, there are not many long periods when the house is unoccupied.
I target the long run time to maximize efficiency. A 160°F pipe will lose more heat to the part of the building that I don’t want to heat as well as more heat to the wall right behind the radiators. It also results in the house going micro too-hot, too-cold, too-hot, too-cold as it cycles. Mine is constantly trickling in just enough heat to replace the heat lost instead of cycling between adding way more than needed then none for a while.
Another large effect is that low return water temperatures into the boiler allow for greater condensation of exhaust gas energy to be used in the building instead of sent outside. Walking by my house on a cold day, you’ll see minimal steam plume during operation. All that steam I see my neighbors emitting is energy they paid for and delivered to the outside… (They paid a lot for a boiler with a 95% or 98% sticker and run it at 80% efficiency.)
> Another large effect is that low return water temperatures into the boiler allow for greater condensation of exhaust gas energy to be used in the building instead of sent outside.
Correct.
> Walking by my house on a cold day, you’ll see minimal steam plume during operation. All that steam I see my neighbors emitting is energy they paid for and delivered to the outside… (They paid a lot for a boiler with a 95% or 98% sticker and run it at 80% efficiency.)
Please check your assumptions.
A boiler operating in condensing mode will produce a trickle of liquid condensate (that may well be drained somewhere that you can’t see [0]), teeny tiny drops of condensate suspended in gas (colloquially “steam”, but it’s more like fog), and some residual water vapor mixed with the exhaust gasses. You can see the “steam”, but you cannot see that residual vapor except to the extent that it condenses further as the exhaust stream cools after it exits, much as you can see some of your own exhaled water vapor on a cold day as it condenses outside your nose or mouth. The exhaust gas is saturated: it has maximum humidity and is at its own dewpoint, so there is a lot of visible fog. The droplets that form inside the boiler and escape with the flue gas do not represent wasted heat: their heat of fusion has been captured.
A boiler operating in non-condensing mode will produce no liquid condensate, and its exhaust will be well above its own dewpoint. It will contain far more water vapor than a condensing boiler, but you cannot see that vapor except insofar as the flue gas has a different index of refraction than the surrounding air and distorts the background a bit. Depending on weather, a bit of it may condense later. All of it is wasted energy.
[0] This liquid condensate is nasty stuff: it’s basically carbonated distilled water plus some impurities but not usefully buffered, and it’s rather acidic. It will quickly corrode many metals, including copper and many common copper alloys, non-stainless steel, galvanized steel, etc. Non-condensing furnaces and boilers are generally carefully engineered to avoid condensation, because the condensation would damage them. If your plumber is unaware of the degree to which boiler condensate is corrosive and uses copper pipes or metallic fittings (push-to-fit in the style commonly sold as “Sharkbite”), the system will fail. Use plastic pipes (PVC or PEX) and plastic (or maybe stainless steel) fittings such as ordinary solvent-cement PVC fittings, “engineered plastic” PEX fittings, or push-to-connect fittings with plastic wetted surfaces. John Guest makes these, and there is also the somewhat bizarre ProLock brand, which seems to be some sort of joint offering from John Guest and Sharkbite.
sokoloff 4 minutes ago [-]
I’m imagining that what I see in my neighbor’s exhaust is the subsequent condensation as their exhaust gas cools to where the dew point is met and visible moisture becomes apparent.
I can see a clear difference between running my own boiler at 25°F OAT (lots of “steam”) versus 40°F OAT (almost none) while I see my cross-street neighbor showing large plumes on both. I’m not sure if I mistyped above or I’m actually thinking about it wrong, but I don’t think my observations are incorrect.
Having that water condense outside the building (giving up heat to the neighborhood) is less efficient than having that water give up its heat into the incoming (return) water.
eru 2 hours ago [-]
Btw, a heated blanket would be a lot more efficient, as it warms just your butt.
sevensor 49 minutes ago [-]
Heated blankets are ok, but you have to arrange them just so, and then you can’t move without fussing with the cord. It’s the last resort after layering warm clothes before bumping up the thermostat.
Retric 4 hours ago [-]
> A 160°F pipe will lose more heat to the part of the building that I don’t want to heat as well as more heat to the wall right behind the radiators.
You’ve got the first part of that backwards, it’s the walls near your radiators that are your problem and need more insulation.
sokoloff 4 hours ago [-]
Indeed the building is 100 years old and impractical to retrofit insulation in any cost-efficient way (structural brick, lathe and plaster walls with about 1” of air space in the original parts of the building).
frereubu 2 hours ago [-]
Thanks for the explanation.
sz4kerto 4 hours ago [-]
> If your goal is saving energy/money, you don’t want a system capable of going from cool to toasty in 20 minutes.
Depends. As explained in a sibling comments, I have some rooms that have combined UFH and radiators, and if the desired temp is more than 1 celsius away from the current temp, then both are driven, otherwise it's just the UFH.
sokoloff 4 hours ago [-]
Indeed “depends” is almost always the answer.
So long as you can get the boiler return water temps low enough, you can operate the boiler in its high efficiency range.
Most dual-temp setups are set for the highest temp and mixed-down to provide the lower temp for under-floor. That’s cheapest in terms of equipment and install but cannot be as efficient as a system that mixes down when both loads call but also lowers flow temp (thereby lowering return temp) when no high-temp rads are calling.
quickthrowman 1 hours ago [-]
This is a great post which describes how most commercial boilers are controlled. I’m looking at a sequence of operations for a boiler project I did recently and the hot water supply setpoint for -20F outdoor air is 145F and for +45F the hot water supply setpoint is 120F.
Most home boilers lack an outdoor air reference temp sensor but all commercial boilers have them.
DecoPerson 5 hours ago [-]
The Flipper Zero is great, and could handle all of the hacking/investigation part by installing custom firmware.
The original product understandably arrives with heavily-restricted firmware (I imagine to reduce the amount of flak the company receives). However, it is incredibly easy to install Flipper Unleashed or similar, which removes all said restrictions and adds a lot of additional functionality.
Possessing the tools that could be used to commit a crime is not necessarily a crime in and of itself! Just be careful with what you do or, depending on what country you’re in, you might find some men in suits knocking at your door.
Personally, I wanted to replay “encrypted” 433MHz signals for my own devices (electric gate, roller door, roller shutters, …) and this was disabled with the Flipper’s region set to Australia.
0xEF 4 hours ago [-]
> Possessing the tools that could be used to commit a crime is not necessarily a crime in and of itself!
While I do agree 1000%, I also want people to be careful with this thinking since I have gotten in some minor trouble in the past. Always assume the authority questioning you can and will create whatever narrative they wish, that it will be accepted, and that your own reasoning will likely be used against you.
I will always encourage exploration and curiosity in tech, but if we stick with the Flipper Zero example, there's a few things one should keep in mind, regardless of the jurisdiction they're in:
* Don't carry it around unless you intend to use it.
* Read all documentation before you start practicing, then practice being subtle.
* Taking a note from my outdoorsy side, adopt the "leave no trace" ethos.
* Pay attention to the effect your presence and actions have on the environment and your target and how that might be interpreted by an outside observer, then take action to mitigate suspicion.
These apply to lots of devices, everything from your disposable smartphone to a cheap RFID card copier from Temu.
Our eagerness sometimes gets the best of us, especially new-comers, and we want to jump to the part where we can be like the hackers we see in tv and video games. There's a reason those guys are fictional characters. Innocuous actions or not, the perception of the authority questioning you is all that will matter, in the end.
crtasm 44 minutes ago [-]
Or perhaps go for the opposite of subtle - in many places it's quite normal to see people in hi-vis vests taking readings etc.
0xEF 4 minutes ago [-]
That's an excellent additional thing to consider and I'm a bit mad that I neglected it since I have accidentally been that guy.
My job requires me to wear hi-vis (as well as other PPE) and it is crazy how little security pays attention to me in some of the very-big-name plants I visit, often with a laptop bag full of flash drives and a bunch of other tools that allow me to get into the machines.
Early in this part of my career, I found myself in a very large plant for the first time, and my escort got pulled away on some other task (I now expect this to happen since it's such a common occurrence), leaving me to fix the machine I was working on. The place was the size of a small town, and I needed to use the restroom, but nobody was in the vicinity to ask, so I did my best to follow the floor markings and signs. Found it, but took a wrong turn coming back and found myself in a completely different area. Since I was new, I tried to find my way back without asking anyone I saw because I did not want to look stupid, but nobody stopped me, questioned me, etc.
Probably one of the best lessons in social engineering is looking like you're supposed to be there.
butlike 19 minutes ago [-]
The 'shade curve' as I call it, where one reaches a point where their actions could be considered so shady, it's automatically assumed it couldn't possibly be them.
Smoking pot in a dark parking lot with friends at night gives more cover, but smoking pot walking down your city's main street in the middle of the day gives you the cover of just smoking an innocuous "rollie," like any other person could be.
smelendez 7 hours ago [-]
I wonder what the ideal one-size fits all thermostat looks like.
The one in my apartment has a “feature” a lot of US thermostats now have, where you set four ordered times called wake, leave, return, and sleep and the temperature you want the space in each interval. I know very few people who actually live in a household where everyone wakes, leaves, returns, and sleeps on the same schedule every day.
I work from home and personally just want to set a temperature and have the space stay at that temperature indefinitely but this system requires that I tap through and enter the desired temperature four times, while confirming the four intervals.
I guess I’d be happier with a more programmable thermostat that I could set to behave like an old school dial thermostat.
Cthulhu_ 6 hours ago [-]
I'm still of the opinion that a dial works best. Especially in modern homes (in Europe at least), there seems to be a school of thought that you should just leave your thermostat at the same temperature at all times - the theory being that warming up a cold house in the morning costs more energy than maintaining a stable temperature.
Anyway, my ideal setup would be to install 'smart' thermostat taps on every radiator in the house, either manually turn them down when you're not in the room or have them automatically detect activity or open windows and adjust accordingly. But each one has the authority to trigger the central boiler if needs be, instead of only the master thermostat in the living room.
tgsovlerkhgsel 5 hours ago [-]
> the theory being that warming up a cold house in the morning costs more energy than maintaining a stable temperature
This is only true if the heating happens quickly and the system is less efficient when heating quickly. Otherwise, this doesn't make sense from a physics standpoint. A temporarily lower temperature differential means less kWh of heat lost.
DamonHD 4 hours ago [-]
This is a whole research topic, my PhD in fact!
FWIW I run my heat pump intermittently and with locally-smart TRVs that get to call for heat centrally, and a weather compensation only flow temperature curve, and it WORKSFORME!
Heating systems generally are more efficient when they need to output less power. Whether that cancels the increased heat loss seems to be a question that can’t be answered in general.
rightbyte 4 hours ago [-]
"Quickly" implies higher power which will make the air around radiators warmer than a slow heating.
The losses are proportional to the temperature differential between outside and inside.
So you should have somewhat higher losses from the hotter air streams from the radiators passing the windows.
Dunno about magnitude though.
vladms 5 hours ago [-]
I think in real life there are more constraints. For example there are people that sleep better at a lower temperature than the daily one (so leaving the thermostat at the same temperature it's a minus for them).
Regarding "what is better" from energy efficiency, I would prefer a system that "check it" because my guess is that it depends a lot based on the individual situation. I mean everybody is going crazy over "IA" but a couple of sensors and a system smart enough to adjust your usage based on your particular situation and preferences (like "eco", etc.) is an exception.
alistairSH 5 hours ago [-]
In slightly cooler climates, the answer for sleep is to open windows. This works in much of Europe, even through summer.
But of course, not really feasible in Atlanta or Phoenix. Nighttime temps are too warm.
eru 2 hours ago [-]
We are talking about places that need heating here.
In general, you should either run the heater or have your window open. Both at the same time is bad news for your energy bill.
deno 5 hours ago [-]
Open windows in a city often means you are invinting in pollution, both air and noise.
eloisant 3 hours ago [-]
> the theory being that warming up a cold house in the morning costs more energy than maintaining a stable temperature.
That's true if you completely stop heating. However if you lower the temperature by roughly 3.5C when you're not home, you'll be saving energy.
So you can for example program it to be 16C when you're out and 19C when you're in. You don't completely turn off heating indeed.
KineticLensman 4 hours ago [-]
(UK) my boiler has a control with something like the wake..leave timer (it actually has six settings for a midday period as well) and there is a separate thermostat with a temperature dial. The boiler also has a button that advances it to the next time interval if you want instant on (eg if you come home early to a cold house). I find this combo of controls meets all of my needs, given that I have a fairly repeatable daily schedule.
wickedsight 5 hours ago [-]
> the theory being that warming up a cold house in the morning costs more energy than maintaining a stable temperature
I've heard this theory a lot too, but it doesn't match with physics. A warm house loses more energy than a cold house, due to a higher temperature difference allowing easier heat transfer. So in most homes, with radiators and high temperature CV, it's way more efficient to just turn it off when you gone.
One exception is when you have a very well insulated house, combined with floor heating and a very efficient, low temperature heat pump. In this case, it takes a lot of time for temperature to move in the house and it's already incredibly efficient.
sz4kerto 4 hours ago [-]
It does match physics if you consider other factors. Apart from the heat pump scenario, this statement can also be true when you have condensing boilers (and okay-ish insulation)
The reasoning: when you heat up the house, then your boiler needs to produce constant high-temperature water. When you keep the house at the same temperature, then the boiler produces much lower temp water and it is more efficient.
Insulation also matters because if your house has outer insulation then it means that heat transfer from the house to the environment is mostly blocked, but cross-room heat transfer is likely not (through the walls). Therefore it is better to heat the whole house than heating just a couple of rooms because if you do the latter then you'll end up heating the whole house anyway but you're using less surface area (meaning you need higher flow temperatures, meaning less efficiency).
eru 2 hours ago [-]
> The reasoning: when you heat up the house, then your boiler needs to produce constant high-temperature water. When you keep the house at the same temperature, then the boiler produces much lower temp water and it is more efficient.
How does your boiler produce heat for your water in your scenario?
> Therefore it is better to heat the whole house than heating just a couple of rooms because if you do the latter then you'll end up heating the whole house anyway but you're using less surface area (meaning you need higher flow temperatures, meaning less efficiency).
Just model the other rooms as very weird wall to the outside.
miunau 5 hours ago [-]
We've used the Tado system with a central boiler and smart radiator knobs for a few years. It's worked fine and hooks up to Home Assistant and can do the things you describe. I'm sure there are some alternatives.
Freak_NL 7 hours ago [-]
Isn't this pretty much what these thermostats already allow? I have a new Honeywell Thermostat which basically does what the twenty years old one it replaced does with a few added conveniences in terms of UI. It has those wake/leave/return/sleep instants for each weekday (but also adds an optional second leave/return pair), and it has an option to override the day programme to 'holiday', which is essentially an eighth programmable weekday you can activate at any time.
Your use case is possible with that. Just set the standard program to 15°C, and activate the holiday set to whatever you need whenever you want. Configure it to go to 15°C at some sensible time in the evening, so it won't go on even if you forget it.
tgsovlerkhgsel 5 hours ago [-]
The obvious solution is a "wake time" of 8 am, "leave time" of 8:01, "return" 8:02, "sleep" 8:03. Then just set the sleep temperature to your desired temp and the remaining ones to something reasonably close, or if it doesn't automatically switch between heating and air conditioning, set it for the no-op for the season (i.e. the highest possible temp in summer, and the lowest possible in winter) for those three minutes.
bob1029 5 hours ago [-]
> I wonder what the ideal one-size fits all thermostat looks like
My wife and I worked a six-week shift work schedule for a long time. We got second-gen nest thermostats when they first came out (2012) thinking they were neat.
Nope! The smart learning feature was the biggest pain in the ass. You’d be sleeping during the day for a night shift, only to find yourself freezing because it decided no one was home.
uptown 3 hours ago [-]
You can turn off the feature that changes temp based on presence. Or disable dynamic scheduling altogether.
xattt 28 minutes ago [-]
I ended up having to manually changing the schedule week-to-week.
ThePowerOfFuet 5 hours ago [-]
> I wonder what the ideal one-size fits all thermostat looks like.
As you go on to describe, there probably isn't one.
willvarfar 9 hours ago [-]
I guess your toolbox really shapes your solution space thinking; as I read through this, being completely lost in the whole world of RF whatnot, my mind jumped straight to an alternative attack that better fit my own tooling: could you encase the thermostat in a box that you can mechanically control the temperature of?
haileys 8 hours ago [-]
I removed the thermistor from inside my wall controller and wired in a digital pot instead. Achieves the same thing without physically heating and cooling the sensor
avidiax 8 hours ago [-]
This sounds good, except that cooling a box is problematic. He needs the temperature sensor to read low so that it turns on the heat.
That said, if he has access to the interior of the thermostat, I'm sure it won't be difficult to replace the temperature sensor with a circuit to cause it to read either really high or really low on demand.
dtech 7 hours ago [-]
For such a minor use case a peltier element is suitable. Very energy inefficiënt but you don't need much and it can both heat and cool.
willvarfar 7 hours ago [-]
I was literally imagining duck-taping one of those cheap electric "instant cooling" cups over the box on the wall, and running a small incandescent bulb in to be the heating up element.
toast0 8 hours ago [-]
> This sounds good, except that cooling a box is problematic. He needs the temperature sensor to read low so that it turns on the heat.
Ice pack and desiccant?
kbuck 9 hours ago [-]
Or attach an ESP32 to the boiler's control board that closes a dry contact circuit...?
mschuster91 7 hours ago [-]
The problem is, if your landlord ever comes around for inspection, or the bloody thing breaks down due to your installation attempt, you can be held liable up to and including getting evicted.
unsnap_biceps 9 hours ago [-]
That was my first thought on how I would approach it as well.
nippoo 7 hours ago [-]
Yes! You can indeed do exactly this. Look up CoolBot - they do exactly this, by just heating up the existing thermostat
mjlee 8 hours ago [-]
Or, assuming they have physical access to the combi boiler, removing the receiver unit and replacing it with a more Home Assistant friendly combi boiler thermostat.
Probably a 30 minute job if you’ve never done it before and easily reversible with a little bit of double sided sticky tape, which all Brits should be familiar with if they ever made a Tracy Island. There is a real risk of electrocution which could be completely militated against by turning off the power to the boiler.
Still, a fun hack, and nicely executed!
anal_reactor 7 hours ago [-]
I've heard a story of people renting an apartment with locked thermostat to the legally allowed minimum. Tenants would put ice on the thermostat
Gazoche 5 hours ago [-]
I heard that was a well-known trick at my old uni dorm. There was a single thermostat for the whole floor so once people figured out where the sensor was, the ones who lived closest to it would often leave packs of frozen food on it.
thomashabets2 8 hours ago [-]
If you do want to decode it, it's probably not that hard. I was going to implement the transmission side when I did this, but then I moved.
Speaking of newish natural gas (CH4) heaters, they all should have modulating thermostat capability with OpenTherm/eBus or other protocol. Combined with a thermostat with outdoor temperature sensor system efficiency is increased a few percent and that should help offset thermostat and installation costs. In the end you have more efficient modern heating system.
Same should apply for heat pump systems.
steelegbr 6 hours ago [-]
OpenTherm is a cool idea but even new installations aren't always wired for it. When installing a new smart thermostat I found the installation has been wired as S Plan with the few cables running between the boiler location and valves location already consumed. Makes the job much bigger if you're not prepared for it.
yurishimo 8 hours ago [-]
If OP ever shows up here, you probably could have just replaced the thermostat with one that is compatible with your boiler for less money and headache. The boiler market is fairly open to competition as evidenced by the fact that you could find a Honeywell signal in a random OSS project that also worked.
Good luck with your future apartment customizations!
glitchcrab 7 hours ago [-]
I think you missed where it was explained that the apartment is rented and therefore you cannot modify anything.
Griffinsauce 7 hours ago [-]
Cannot modify irreversibly though right? Something like a Nest or whatever is easy to return to the original state when you leave.
odiroot 7 hours ago [-]
Replacing a thermostat is very easy to do though. And very easy to revert too.
Usually it's just acting as a simple relay (on-off switch) so there's two physical wires.
I've got my Hive thermostat running great with various Bosch and Vaillant boilers. And it works great with HA.
Some newer boilers have 12V "smart" controls but still expose 230V "dumb" call for heating pins.
Tarq0n 4 hours ago [-]
OP's thermostat wasn't wired, that's why he'd need the electrician.
glitchcrab 5 hours ago [-]
Agreed (I set up our dual zone Nest-controllee heating so I know it's not difficult), but what happens if the landlord visits and isn't happy with you having done this? It would be a pain to have to revert this if you knew the landlord was coming.
mschuster91 7 hours ago [-]
> Usually it's just acting as a simple relay (on-off switch) so there's two physical wires.
Vaillant has a proportional signal as well, and that thing in my old home was 30 years old... [1]
> The only thing I'm not happy with is needing to use a very powerful and versatile radio like the HackRF for something as simple as a boiler on/off switch. But I'd rather use something overkill and have it work than spend ages trying to force smaller radios to do my bidding.
All the apartments I lived in had basic thermostats; and I even rewired and replaced one of them.
What was blocking Videah from buying an off-the-shelf thermostat?
simooooo 2 hours ago [-]
I’ve got a similar problem, and plan to replace the thermostat with a Shelly relay which can be toggled by home assistant’s events based on the TRVs in each room.
Then the boiler is basically controlled by the relay.
MisterTea 1 hours ago [-]
Instead of attacking a radio controlled relay, the author should have read up on how their heating system works. All they need is a relay controlled by an internet connected thing to replace the thermostat receiver. I could understand if the receiver was locked away but the video clearly shows they have access to the boiler.
wpietri 50 minutes ago [-]
That leaves very visible evidence that things have been hacked. Any time the landlord comes around you'd want to remove that. And if there's some sort of infrastructure emergency (plumbing problem, heat goes out, fire in the building) it could be very challenging to get there and remove all traces before the landlord is stomping around.
MisterTea 27 minutes ago [-]
Why would you bee that paranoid? What laws exist in the UK where this is so illegal as to be that paranoid?
That's a level of paranoia I would never have. You can easily conceal them in a way that is almost imperceptible.
sz4kerto 4 hours ago [-]
We've moved to an new apartment (house) and we had to do a full renovation. It doesn't have modern insulation and I calculated that for the time being the ROI on insulation isn't worth it. It's a multi-floor semi-detached house and I wanted the best comfort and the most economical heating possible.
In particular: stable and individually adjustable temperatures for bedrooms and living rooms; underfloor heating in some rooms (bedrooms), radiator-based heating in some others (living room), and combined UFH+radiators in some others (where UFH might not be enough during extreme colds).
I thought I can just pay someone some money and they'll set up the controls for me. It must be a simple exercise, right?
I could not have been more wrong. After spending a few hours of understanding the setups that "experts" have recommended, I figured out edge cases where they would be either wasteful or uncomfortable (meaning: unnecessary and inavoidable temperature overshoots or undershoots, etc.). I had many-many rounds with Honeywell, Tado, Siemens, etc. and every single one of them had _major_ issues.
The renovation got a bit stuck because of this, but the plumbing was ready so I wanted to see whether the pluming and pumps are working, at least. So I connected the pumps and valves to "smart plugs", i.e. Zigbee-controlled plugs, so that I can see that they turn on. They did, which got me thinking...
Right now I have $20 Zigbee temp sensors sprinkled across the house, $30 smart plugs and relays driving valves, pumps and the boiler, and Home Assistant is controlling the whole thing. Everything works perfectly and I could implement some features that simply no system would have done out of the box, for example in rooms where there's combined UFH and radiators I can drive both heating systems when the target temperature is far from the desired (so that the room heats up quickly) but as the room temp is getting closer to the target, the radiators are turned off so that UFH dominates heating (more comfortable and more energy efficient than radiators). In rooms with radiators, temp is +- 0.4 C within target, in rooms with UFH, it's +-0.1C within target.
darkwater 4 hours ago [-]
Yeah, the automated/remote controlled heating system world, and also the ringbell world is basically a giant scam, since they are updates on world that also scammed you in the past. I cried when I shelled out so much money for my Tado device, but even a dumb bTicino device costed in the hundred of euros realm, and it's just a sensor + a small LCD display and a designed-in-hell menu system to program it. And the same happens in Ip-based ringbells. A Doorbird will cost you hundreds of euros for what is basically a webcam plus some nice metal casing and a shitty software, but it competes with analog systems with optic cables etc that cost basically the same or more.
cameronh90 2 hours ago [-]
Off the shelf systems aren't only optimised solely for efficiency. They're made to be simple enough that an installer with half a day's training can do a few multiplications and additions to set the parameters that'll give you a tolerable percentage of optimal in the situations that equipment is specified for -- while still being understandable by the next guy. This nearly always means things are a bit oversized and inefficient to account for the things that the simple models are missing.
Almost everything in engineering is like this, not just heating. It's pretty rare that something is fully optimised.
sokoloff 3 hours ago [-]
For every John Siegenthaler and Dan Holohan, there are thousands of mechanical engineers and tens of thousands of plumbers who are happier to slap in a $20K 4-hour boiler retrofit. There’s not enough extra money in catering to the 0.1% of homeowners who care about the details.
rightbyte 4 hours ago [-]
Sounds like a nightmare for a future buyer to operate.
Some people are unlucky enough to buy homes where a machine engineer designed the boiler setup and the boiler room have enough valves and manometers to like operate the engine of Titanic.
I guess programmers are the new sinners in this area nowadays.
sz4kerto 3 hours ago [-]
If we ever sell this (which we don't plan to), I know what to install (it'll be quite good, just not this perfect). I have it in a cupboard (a Siemens Connected Home thermostat system), the downside of that is that the combined UFH+radiator rooms will be less comfortable.
(But still more comfortable than 99% of the houses I've been in.)
I haven't mentioned in the parent comment but as a test I've dismantled the HA system and installed the Siemens system and it works well, just not 'perfectly'.
rightbyte 2 hours ago [-]
Sounds well thought out. Many seem to forget designing for replacing.
In generall I think all these IoT systems will be a major headache as they age.
My thermostats on the radiators are 45 year old by now. That is kinda the expected service life we are used to.
evrimoztamur 4 hours ago [-]
The existing professional setup was also a nightmare, what gives?
rightbyte 4 hours ago [-]
Well first of I am envious and I would want to do something similar.
If I inherit a heating system I want it to be all mechanical except maybe the control system for any heating pump.
amne 3 hours ago [-]
a bit off-topic: Are you running a single boiler and if so, how are you mixing UFH with radiators given there's a ~20C difference between the recommended temps for the two?
My knowledge is that for UFH you run at temps between 40-50C and radiators run at 60-70*C.
sz4kerto 3 hours ago [-]
UFH has mixing valves, so it runs on 38 C and radiators run on 55C. Single boiler.
aboardRat4 2 hours ago [-]
In the former Soviet Union we just have central heating
The government maintains indoor temperature at 24 degrees from October to May, and the water is heated at the power stations.
robocat 4 hours ago [-]
> sledgehammer approach
A hammerier solution would be to control the temperature seen by the thermostat (ignore the difficult RF protocol).
A heating element and a temperature reading could control the heat seen by the thermostat.
I'm pretty sure you wouldn't need any cooling (Peltier or whatever). Just a heater and ambient cooling! Set the thermostat to a high temperature, and run the heater to make the measured temperature hotter: when you don't want the heating to run.
That said, I think hacking the RF protocol is geekier and far awesomer.
> rpitx is a general radio frequency transmitter for Raspberry Pi which doesn't require any other hardware unless filter to avoid intererence. It can handle frequencies from 5 KHz up to 1500 MHz.
Wait, how does that work?
1.5GHz is a _lot_, I can't imagine this is done with bit-banging an I/O line, nor do I expect the Pi will have a DAC with anything close to a 3GHz+ sample rate.
> Plug a wire on GPIO 4, means Pin 7 of the GPIO header (header P1). This acts as the antenna.
A bit of Googling shows me that on the later Pi board GPIO4 (pin 7) has a bunch of alternative modes, amongst which is a general purpose clock output (GPCLK0), a DPI output bit (DPI_D0) and what I recon is composite analog video in/out (AVEOUT_VID0, AVEIN_VID0), and the TDI JTAG pin. But none of these would get close to 1.5Ghz TRX capabilities, no?
What's the magic here?
solarist 6 hours ago [-]
RF is basically black magic but here it’s the harmonics of lower frequencies that are in GHz range (and very noisy and weak)
YakBizzarro 7 hours ago [-]
Funny how the manufacturer proudly claims that the protocol is encrypted, but completely forget to mitigate replay attacks,thus making the encryption completely useless
kleiba 7 hours ago [-]
Which raises the question whether the OP now unknowingly also controls the heater in the apartment next to his...
mhw 1 hours ago [-]
Unlikely. This kind of wireless thermostat has two parts: the thermostat itself, and a separate receiver box that's directly connected to the boiler. There's usually a pairing process that you can go through where the two parts negotiate a shared value used in the protocol; this prevents one thermostat unintentionally controlling other boilers. You can see this described in the Installation Guide for the thermostat linked from the article (it's called 'binding' in the guide).
simooooo 2 hours ago [-]
Probably not otherwise the original would also potentially run that risk
mattigames 6 hours ago [-]
And so the heat-stroke-killer was born, offing his victims with rapid changes between coldest and hottest setting, natural death has never been this human-made.
globular-toast 6 hours ago [-]
Ah yes, the classic problem of people using crypto primitives without fully understanding the problems they're trying to solve. Anyone even remotely interested should look into a full protocol like TLS or PGP to see how many primitives like block ciphers, hashes, etc. are involved and why.
rsynnott 4 hours ago [-]
Some risk of collateral damage in the form of randomly controlling other peoples' boilers if your transmitter turns out to be more powerful than the one in the thermostat, tho...
frontlodjkgi 4 hours ago [-]
I imagine even encrypted messages could be replayed if the protocol wasn't designed against it. It also doesen't say what kind of encryption it uses, it could be a very weak in-house "encryption", for all we know it could be only an unknown encoding.
gRoberts84 3 hours ago [-]
I went through various stages of this myself and got an Sonoff RF Bridge, that allowed me to capture and replay RF via Home Assistant. In the end though, it was always easier to use an off the shelf solution, especially for boilers. OpenTherm with Tado worked perfectly.
__turbobrew__ 7 hours ago [-]
The legit Hackrf One is known to have frequency smearing, I wouldn’t use one off Aliexpress to transmit without testing it with a spectrum analyzer first (which you probably don’t have if you are buying knockoffs from Aliexpress).
tgsovlerkhgsel 5 hours ago [-]
The blogpost mentions "I guess it's always good to have another SDR just to confirm that we're not polluting other frequencies." and they have an RTLSDR which probably could serve as a good enough spectrum analyzer for this use case?
KeplerBoy 6 hours ago [-]
What does frequency smearing mean in this context?
tgsovlerkhgsel 5 hours ago [-]
You're trying to transmit (only) on e.g. 433 MHz, but you actually transmit on 433 MHz and a bell curve around it.
KeplerBoy 29 minutes ago [-]
so, severe LO clock drift?
Mond_ 7 hours ago [-]
Cool as fuc + very nice blog design.
pyfon 5 hours ago [-]
Furry cartoons are catching on.
josefritzishere 31 minutes ago [-]
For a related hack... If your apartment building with a BACnet system, it also relies on a set of commands for heating and cooling. Assuming you are on the same VLAN as teh server, you can inject commands. The difficulty is that every BACnet server is somewhat different, though most have spec online.
epsilonaurigae 33 minutes ago [-]
OP removed their comment section, but if you’re here:
I haven’t done this since 2014 but the google nest API used to (hopefully still does?) let you see and or set the thermostats status with curl commands.
My use case was to run one shell script that got my burglar alarms status, and if it was “armed/away” to simply set my nest thermostat as away, too.
But it can also be hooked up to a dummy load or a relay and just used as an indoor temperature sensor.
And the curl commands OP is relying on can be tied in to indoor and outdoor temperatures , such as scraping local weather with curl/wget and based on that integer, turning the boiler to a minimum when it’s a certain temperature outside.
Or turning it completely off when it’s warm outside.
I’m about to revisit this again just because I have an ancient gas pig of a furnace that uses microvolt and is too cold when it’s cold outside, and too hot when it’s warm outside.
So I need one thermostat in place to turn it on no matter what at 40F, but then some conditional logic to kick that thing on and off on different cycles based on outdoor temps. The whole systems too crude to implement one off the shelf without adding a zone controller, so I just want a Linux box at home to be the zone controller….
where I differ is that I’m not sending an RF signal to the boiler, I just have to close an NO contact to engage mine (and I’m lazily going to use the nest for that.)
If anyone knows of a better thermostat that has its own API I can set, read sensors, turn hvac on and off without using google/nest account or having a dependency on the goodwill of their API existing forever , I’ll come back and glean any responses thanks in advance.
As an afterthought, hm I can just attach temperature probes and a GPIO for a relay and indoor/outdoor temps and do away with google/nest altogether…. Thanks for jogging my brain a bit I might do exactly that.
(The nest was cool , and educational, I guess, 12 years ago when I didn’t know how to really do anything but run and fire off curl commands on someone else’s hardware for temp sense and closing a relay and I don’t have anything bad to say about it as a starting point.)
Where I was going with this , though, was that , you could use an off the shelf nest , and run
1) one command against API to get thermostat status (system thinks it’s on or off , even though it’s factually not directly controlling anything) and then based on that,
2) another command to your RF board to transmit a matching signal.
…
(However you could also do the same with a temperature probe that can be read on board or over WiFi , and then manage your setpoints in the script and or by other means: eg scraping a weather site for the local outdoor temp in your case where the landlord probably wouldn’t let you attach or connect an outdoor probe.)
Bonus with the nest approach is you get a dial, can mount it on anything , doesn’t have to be the wall of your unit… and it “sort of works” like a normal thermostat as well, as soon as the shell script reconciles the two states manually.
Long winded rant but the original use case was an apartment where the thermostat was proprietary and serialized data and I didn’t have any option to integrate a smart thermostat other than turning it to its maximum set point and then using the nest with a massive 220V/50A HVAC relay to just chunk the AC power line on and off on demand.
alistairSH 5 hours ago [-]
Is this a non-standard thermostat control mechanism? I don’t know what’s common in apartments. All my houses have the thermostat wired to the HVAC (and are easily replaceable by the resident).
badmonster 7 hours ago [-]
loved the blend of reverse engineering and persistence
T3RMINATED 2 hours ago [-]
[dead]
pinoy420 7 hours ago [-]
[dead]
poopiokaka 4 hours ago [-]
Being a furry is objectively not okay
Rendered at 14:29:45 GMT+0000 (Coordinated Universal Time) with Vercel.
It seems like the easier hack would be to put a peltier heater/cooler under the thermostat then control that remotely to assume control over what temperature the thermostat sees.
The link to the exact model of thermostat isn't working, so I don't know how amenable its design is to this approach, but the thermostats I've used are generally wall-mounted and putting a heat/cool source under them wouldn't be too hard. You'd need to make sure that you didn't send both the heat and cool into the thermostat, but that's a simple positioning problem.
If your goal is saving energy/money, you don’t want a system capable of going from cool to toasty in 20 minutes.
Instead, you want a system that runs (much) lower water circulation temperatures (giving lower losses in the unconditioned spaces and more even room heating). That can be done to any condensing boiler by just turning down the flow target temperature.
A second layer of optimization on top of this is the addition of outdoor reset/weather compensation which will adjust that flow temperature based on the outside temperature, giving a flow temperature than can just barely restore the building to the desired setpoint temp.
With mine properly tuned, I was targeting having the thermostat act more like a high-limit and for it to call for heat between 22 and 24 hours per day while not overheating the house. That often meant flow temps in the 110°F (warm day) to 135°F (below freezing day) range. Compared to the prior winter (at a constant 160°F flow), the house used 8-15% less gas and was wildly more comfortable. (This setup does preclude using deep setback settings, which also can save money, because recovery times are necessarily long in such a scheme, unless you have an even smarter control system that can run perfectly tuned water most times but hotter water during recovery from setbacks.)
Energy moves from hot to cold linearly with temperature differences. Hypothetically, if the pipe was the same temperatures as the inside of your home all the heat transferred would be outside the envelope. The hotter the pipe the better this ratio becomes. This is true regardless of what percentage of the pipe is inside the envelope.
However, heating along the exterior of the home under windows and such then you’ll heat the exterior walls to higher temperatures than the interior thermostat thus losing more heat to the outside. Radiant heating on the other hand largely avoids this effect.
In New York, at least - the standards were never changed to accomodate for closed windows in 1920. Snopes has a rundown. https://www.snopes.com/fact-check/apartment-radiator-pandemi...
(not a native speaker here)
The other variable is how well controlled your heating is. A lower flow temperature means less overshoot of the target set point - and as losses scale linearly with temperature delta, that can mean higher energy losses (depending on the characteristics of the controller of course).
Whether or not you care about losses in unheated spaces depends on your system topology. Personally, all my heating pipes are within the thermal envelope of my house, so flow temperature has no bearing on those losses at all.
If you had a resistive electric boiler, flow temperature would have absolutely no effect on efficiency. You'd be completely right, that running heating only when you needed it would be more energy efficient.
50 years ago this was _always_ the case, but condensing boilers and especially heat pumps muddy the waters a little. Condensing boilers can be close to 100% efficient (vs ~70-80% for ye olde gas boilers), but generally only at a fairly specific operating temperature, which may be lower than you'd need to get a rapid rise in temperature. Heatpumps are >100% efficient (that is for every joule of electricity you put in they move more than one joule), but are even more fussy about operating temperature.
The answer now is going to be a solid 'it depends', based on behaviour of the heating system, outside temp, desired inside temp, insulation...
I target the long run time to maximize efficiency. A 160°F pipe will lose more heat to the part of the building that I don’t want to heat as well as more heat to the wall right behind the radiators. It also results in the house going micro too-hot, too-cold, too-hot, too-cold as it cycles. Mine is constantly trickling in just enough heat to replace the heat lost instead of cycling between adding way more than needed then none for a while.
Another large effect is that low return water temperatures into the boiler allow for greater condensation of exhaust gas energy to be used in the building instead of sent outside. Walking by my house on a cold day, you’ll see minimal steam plume during operation. All that steam I see my neighbors emitting is energy they paid for and delivered to the outside… (They paid a lot for a boiler with a 95% or 98% sticker and run it at 80% efficiency.)
https://kw-engineering.com/how-to-optimize-condensing-boiler...
Correct.
> Walking by my house on a cold day, you’ll see minimal steam plume during operation. All that steam I see my neighbors emitting is energy they paid for and delivered to the outside… (They paid a lot for a boiler with a 95% or 98% sticker and run it at 80% efficiency.)
Please check your assumptions.
A boiler operating in condensing mode will produce a trickle of liquid condensate (that may well be drained somewhere that you can’t see [0]), teeny tiny drops of condensate suspended in gas (colloquially “steam”, but it’s more like fog), and some residual water vapor mixed with the exhaust gasses. You can see the “steam”, but you cannot see that residual vapor except to the extent that it condenses further as the exhaust stream cools after it exits, much as you can see some of your own exhaled water vapor on a cold day as it condenses outside your nose or mouth. The exhaust gas is saturated: it has maximum humidity and is at its own dewpoint, so there is a lot of visible fog. The droplets that form inside the boiler and escape with the flue gas do not represent wasted heat: their heat of fusion has been captured.
A boiler operating in non-condensing mode will produce no liquid condensate, and its exhaust will be well above its own dewpoint. It will contain far more water vapor than a condensing boiler, but you cannot see that vapor except insofar as the flue gas has a different index of refraction than the surrounding air and distorts the background a bit. Depending on weather, a bit of it may condense later. All of it is wasted energy.
[0] This liquid condensate is nasty stuff: it’s basically carbonated distilled water plus some impurities but not usefully buffered, and it’s rather acidic. It will quickly corrode many metals, including copper and many common copper alloys, non-stainless steel, galvanized steel, etc. Non-condensing furnaces and boilers are generally carefully engineered to avoid condensation, because the condensation would damage them. If your plumber is unaware of the degree to which boiler condensate is corrosive and uses copper pipes or metallic fittings (push-to-fit in the style commonly sold as “Sharkbite”), the system will fail. Use plastic pipes (PVC or PEX) and plastic (or maybe stainless steel) fittings such as ordinary solvent-cement PVC fittings, “engineered plastic” PEX fittings, or push-to-connect fittings with plastic wetted surfaces. John Guest makes these, and there is also the somewhat bizarre ProLock brand, which seems to be some sort of joint offering from John Guest and Sharkbite.
I can see a clear difference between running my own boiler at 25°F OAT (lots of “steam”) versus 40°F OAT (almost none) while I see my cross-street neighbor showing large plumes on both. I’m not sure if I mistyped above or I’m actually thinking about it wrong, but I don’t think my observations are incorrect.
Having that water condense outside the building (giving up heat to the neighborhood) is less efficient than having that water give up its heat into the incoming (return) water.
You’ve got the first part of that backwards, it’s the walls near your radiators that are your problem and need more insulation.
Depends. As explained in a sibling comments, I have some rooms that have combined UFH and radiators, and if the desired temp is more than 1 celsius away from the current temp, then both are driven, otherwise it's just the UFH.
So long as you can get the boiler return water temps low enough, you can operate the boiler in its high efficiency range.
Most dual-temp setups are set for the highest temp and mixed-down to provide the lower temp for under-floor. That’s cheapest in terms of equipment and install but cannot be as efficient as a system that mixes down when both loads call but also lowers flow temp (thereby lowering return temp) when no high-temp rads are calling.
Most home boilers lack an outdoor air reference temp sensor but all commercial boilers have them.
The original product understandably arrives with heavily-restricted firmware (I imagine to reduce the amount of flak the company receives). However, it is incredibly easy to install Flipper Unleashed or similar, which removes all said restrictions and adds a lot of additional functionality.
Possessing the tools that could be used to commit a crime is not necessarily a crime in and of itself! Just be careful with what you do or, depending on what country you’re in, you might find some men in suits knocking at your door.
Personally, I wanted to replay “encrypted” 433MHz signals for my own devices (electric gate, roller door, roller shutters, …) and this was disabled with the Flipper’s region set to Australia.
While I do agree 1000%, I also want people to be careful with this thinking since I have gotten in some minor trouble in the past. Always assume the authority questioning you can and will create whatever narrative they wish, that it will be accepted, and that your own reasoning will likely be used against you.
I will always encourage exploration and curiosity in tech, but if we stick with the Flipper Zero example, there's a few things one should keep in mind, regardless of the jurisdiction they're in:
* Don't carry it around unless you intend to use it.
* Read all documentation before you start practicing, then practice being subtle.
* Taking a note from my outdoorsy side, adopt the "leave no trace" ethos.
* Pay attention to the effect your presence and actions have on the environment and your target and how that might be interpreted by an outside observer, then take action to mitigate suspicion.
These apply to lots of devices, everything from your disposable smartphone to a cheap RFID card copier from Temu.
Our eagerness sometimes gets the best of us, especially new-comers, and we want to jump to the part where we can be like the hackers we see in tv and video games. There's a reason those guys are fictional characters. Innocuous actions or not, the perception of the authority questioning you is all that will matter, in the end.
My job requires me to wear hi-vis (as well as other PPE) and it is crazy how little security pays attention to me in some of the very-big-name plants I visit, often with a laptop bag full of flash drives and a bunch of other tools that allow me to get into the machines.
Early in this part of my career, I found myself in a very large plant for the first time, and my escort got pulled away on some other task (I now expect this to happen since it's such a common occurrence), leaving me to fix the machine I was working on. The place was the size of a small town, and I needed to use the restroom, but nobody was in the vicinity to ask, so I did my best to follow the floor markings and signs. Found it, but took a wrong turn coming back and found myself in a completely different area. Since I was new, I tried to find my way back without asking anyone I saw because I did not want to look stupid, but nobody stopped me, questioned me, etc.
Probably one of the best lessons in social engineering is looking like you're supposed to be there.
Smoking pot in a dark parking lot with friends at night gives more cover, but smoking pot walking down your city's main street in the middle of the day gives you the cover of just smoking an innocuous "rollie," like any other person could be.
The one in my apartment has a “feature” a lot of US thermostats now have, where you set four ordered times called wake, leave, return, and sleep and the temperature you want the space in each interval. I know very few people who actually live in a household where everyone wakes, leaves, returns, and sleeps on the same schedule every day.
I work from home and personally just want to set a temperature and have the space stay at that temperature indefinitely but this system requires that I tap through and enter the desired temperature four times, while confirming the four intervals.
I guess I’d be happier with a more programmable thermostat that I could set to behave like an old school dial thermostat.
Anyway, my ideal setup would be to install 'smart' thermostat taps on every radiator in the house, either manually turn them down when you're not in the room or have them automatically detect activity or open windows and adjust accordingly. But each one has the authority to trigger the central boiler if needs be, instead of only the master thermostat in the living room.
This is only true if the heating happens quickly and the system is less efficient when heating quickly. Otherwise, this doesn't make sense from a physics standpoint. A temporarily lower temperature differential means less kWh of heat lost.
FWIW I run my heat pump intermittently and with locally-smart TRVs that get to call for heat centrally, and a weather compensation only flow temperature curve, and it WORKSFORME!
https://www.earth.org.uk/heat-pump-16WW-control.html
The losses are proportional to the temperature differential between outside and inside.
So you should have somewhat higher losses from the hotter air streams from the radiators passing the windows.
Dunno about magnitude though.
Regarding "what is better" from energy efficiency, I would prefer a system that "check it" because my guess is that it depends a lot based on the individual situation. I mean everybody is going crazy over "IA" but a couple of sensors and a system smart enough to adjust your usage based on your particular situation and preferences (like "eco", etc.) is an exception.
But of course, not really feasible in Atlanta or Phoenix. Nighttime temps are too warm.
In general, you should either run the heater or have your window open. Both at the same time is bad news for your energy bill.
That's true if you completely stop heating. However if you lower the temperature by roughly 3.5C when you're not home, you'll be saving energy.
So you can for example program it to be 16C when you're out and 19C when you're in. You don't completely turn off heating indeed.
I've heard this theory a lot too, but it doesn't match with physics. A warm house loses more energy than a cold house, due to a higher temperature difference allowing easier heat transfer. So in most homes, with radiators and high temperature CV, it's way more efficient to just turn it off when you gone.
One exception is when you have a very well insulated house, combined with floor heating and a very efficient, low temperature heat pump. In this case, it takes a lot of time for temperature to move in the house and it's already incredibly efficient.
The reasoning: when you heat up the house, then your boiler needs to produce constant high-temperature water. When you keep the house at the same temperature, then the boiler produces much lower temp water and it is more efficient.
Insulation also matters because if your house has outer insulation then it means that heat transfer from the house to the environment is mostly blocked, but cross-room heat transfer is likely not (through the walls). Therefore it is better to heat the whole house than heating just a couple of rooms because if you do the latter then you'll end up heating the whole house anyway but you're using less surface area (meaning you need higher flow temperatures, meaning less efficiency).
How does your boiler produce heat for your water in your scenario?
> Therefore it is better to heat the whole house than heating just a couple of rooms because if you do the latter then you'll end up heating the whole house anyway but you're using less surface area (meaning you need higher flow temperatures, meaning less efficiency).
Just model the other rooms as very weird wall to the outside.
Your use case is possible with that. Just set the standard program to 15°C, and activate the holiday set to whatever you need whenever you want. Configure it to go to 15°C at some sensible time in the evening, so it won't go on even if you forget it.
https://www.honeywellhome.com/us/en/products/air/thermostats...
Nope! The smart learning feature was the biggest pain in the ass. You’d be sleeping during the day for a night shift, only to find yourself freezing because it decided no one was home.
As you go on to describe, there probably isn't one.
That said, if he has access to the interior of the thermostat, I'm sure it won't be difficult to replace the temperature sensor with a circuit to cause it to read either really high or really low on demand.
Ice pack and desiccant?
Probably a 30 minute job if you’ve never done it before and easily reversible with a little bit of double sided sticky tape, which all Brits should be familiar with if they ever made a Tracy Island. There is a real risk of electrocution which could be completely militated against by turning off the power to the boiler.
Still, a fun hack, and nicely executed!
https://blog.habets.se/2017/04/Decoding-FSK.html
Speaking of newish natural gas (CH4) heaters, they all should have modulating thermostat capability with OpenTherm/eBus or other protocol. Combined with a thermostat with outdoor temperature sensor system efficiency is increased a few percent and that should help offset thermostat and installation costs. In the end you have more efficient modern heating system.
Same should apply for heat pump systems.
Good luck with your future apartment customizations!
Usually it's just acting as a simple relay (on-off switch) so there's two physical wires.
I've got my Hive thermostat running great with various Bosch and Vaillant boilers. And it works great with HA.
Some newer boilers have 12V "smart" controls but still expose 230V "dumb" call for heating pins.
Vaillant has a proportional signal as well, and that thing in my old home was 30 years old... [1]
[1] https://www.mikrocontroller.net/topic/126250?page=single
All the apartments I lived in had basic thermostats; and I even rewired and replaced one of them.
What was blocking Videah from buying an off-the-shelf thermostat?
Then the boiler is basically controlled by the relay.
That's a level of paranoia I would never have. You can easily conceal them in a way that is almost imperceptible.
In particular: stable and individually adjustable temperatures for bedrooms and living rooms; underfloor heating in some rooms (bedrooms), radiator-based heating in some others (living room), and combined UFH+radiators in some others (where UFH might not be enough during extreme colds).
I thought I can just pay someone some money and they'll set up the controls for me. It must be a simple exercise, right?
I could not have been more wrong. After spending a few hours of understanding the setups that "experts" have recommended, I figured out edge cases where they would be either wasteful or uncomfortable (meaning: unnecessary and inavoidable temperature overshoots or undershoots, etc.). I had many-many rounds with Honeywell, Tado, Siemens, etc. and every single one of them had _major_ issues.
The renovation got a bit stuck because of this, but the plumbing was ready so I wanted to see whether the pluming and pumps are working, at least. So I connected the pumps and valves to "smart plugs", i.e. Zigbee-controlled plugs, so that I can see that they turn on. They did, which got me thinking...
Right now I have $20 Zigbee temp sensors sprinkled across the house, $30 smart plugs and relays driving valves, pumps and the boiler, and Home Assistant is controlling the whole thing. Everything works perfectly and I could implement some features that simply no system would have done out of the box, for example in rooms where there's combined UFH and radiators I can drive both heating systems when the target temperature is far from the desired (so that the room heats up quickly) but as the room temp is getting closer to the target, the radiators are turned off so that UFH dominates heating (more comfortable and more energy efficient than radiators). In rooms with radiators, temp is +- 0.4 C within target, in rooms with UFH, it's +-0.1C within target.
Almost everything in engineering is like this, not just heating. It's pretty rare that something is fully optimised.
Some people are unlucky enough to buy homes where a machine engineer designed the boiler setup and the boiler room have enough valves and manometers to like operate the engine of Titanic.
I guess programmers are the new sinners in this area nowadays.
(But still more comfortable than 99% of the houses I've been in.)
I haven't mentioned in the parent comment but as a test I've dismantled the HA system and installed the Siemens system and it works well, just not 'perfectly'.
In generall I think all these IoT systems will be a major headache as they age.
My thermostats on the radiators are 45 year old by now. That is kinda the expected service life we are used to.
If I inherit a heating system I want it to be all mechanical except maybe the control system for any heating pump.
My knowledge is that for UFH you run at temps between 40-50C and radiators run at 60-70*C.
The government maintains indoor temperature at 24 degrees from October to May, and the water is heated at the power stations.
A hammerier solution would be to control the temperature seen by the thermostat (ignore the difficult RF protocol).
A heating element and a temperature reading could control the heat seen by the thermostat.
I'm pretty sure you wouldn't need any cooling (Peltier or whatever). Just a heater and ambient cooling! Set the thermostat to a high temperature, and run the heater to make the measured temperature hotter: when you don't want the heating to run.
That said, I think hacking the RF protocol is geekier and far awesomer.
(use at your own risk of course)
> rpitx is a general radio frequency transmitter for Raspberry Pi which doesn't require any other hardware unless filter to avoid intererence. It can handle frequencies from 5 KHz up to 1500 MHz.
Wait, how does that work?
1.5GHz is a _lot_, I can't imagine this is done with bit-banging an I/O line, nor do I expect the Pi will have a DAC with anything close to a 3GHz+ sample rate.
> Plug a wire on GPIO 4, means Pin 7 of the GPIO header (header P1). This acts as the antenna.
A bit of Googling shows me that on the later Pi board GPIO4 (pin 7) has a bunch of alternative modes, amongst which is a general purpose clock output (GPCLK0), a DPI output bit (DPI_D0) and what I recon is composite analog video in/out (AVEOUT_VID0, AVEIN_VID0), and the TDI JTAG pin. But none of these would get close to 1.5Ghz TRX capabilities, no?
What's the magic here?
I haven’t done this since 2014 but the google nest API used to (hopefully still does?) let you see and or set the thermostats status with curl commands.
My use case was to run one shell script that got my burglar alarms status, and if it was “armed/away” to simply set my nest thermostat as away, too.
But it can also be hooked up to a dummy load or a relay and just used as an indoor temperature sensor.
And the curl commands OP is relying on can be tied in to indoor and outdoor temperatures , such as scraping local weather with curl/wget and based on that integer, turning the boiler to a minimum when it’s a certain temperature outside.
Or turning it completely off when it’s warm outside.
I’m about to revisit this again just because I have an ancient gas pig of a furnace that uses microvolt and is too cold when it’s cold outside, and too hot when it’s warm outside.
So I need one thermostat in place to turn it on no matter what at 40F, but then some conditional logic to kick that thing on and off on different cycles based on outdoor temps. The whole systems too crude to implement one off the shelf without adding a zone controller, so I just want a Linux box at home to be the zone controller….
where I differ is that I’m not sending an RF signal to the boiler, I just have to close an NO contact to engage mine (and I’m lazily going to use the nest for that.)
If anyone knows of a better thermostat that has its own API I can set, read sensors, turn hvac on and off without using google/nest account or having a dependency on the goodwill of their API existing forever , I’ll come back and glean any responses thanks in advance.
As an afterthought, hm I can just attach temperature probes and a GPIO for a relay and indoor/outdoor temps and do away with google/nest altogether…. Thanks for jogging my brain a bit I might do exactly that.
(The nest was cool , and educational, I guess, 12 years ago when I didn’t know how to really do anything but run and fire off curl commands on someone else’s hardware for temp sense and closing a relay and I don’t have anything bad to say about it as a starting point.)
Where I was going with this , though, was that , you could use an off the shelf nest , and run
1) one command against API to get thermostat status (system thinks it’s on or off , even though it’s factually not directly controlling anything) and then based on that,
2) another command to your RF board to transmit a matching signal.
…
(However you could also do the same with a temperature probe that can be read on board or over WiFi , and then manage your setpoints in the script and or by other means: eg scraping a weather site for the local outdoor temp in your case where the landlord probably wouldn’t let you attach or connect an outdoor probe.)
Bonus with the nest approach is you get a dial, can mount it on anything , doesn’t have to be the wall of your unit… and it “sort of works” like a normal thermostat as well, as soon as the shell script reconciles the two states manually.
Long winded rant but the original use case was an apartment where the thermostat was proprietary and serialized data and I didn’t have any option to integrate a smart thermostat other than turning it to its maximum set point and then using the nest with a massive 220V/50A HVAC relay to just chunk the AC power line on and off on demand.